HLRS-150DX-ZXY Automatic Rockwell Hardness tester
Product Description
Introduction:
1. Electronic and electric loading, high-precision sensor and unique closed-loop control system are adopted.
2. The z-axis of the worktable rises and falls automatically, and the x-axis and Y-axis directions of the sample table move automatically.
3. Press the start key, the worktable will rise automatically, the sample will be loaded and unloaded automatically after touching the indenter, and the hardness value will be displayed automatically.
4. Touch screen interface, easy to operate, directly select the hardness scale, and the force value will be automatically changed in the test parameters.
5. According to the standard hardness block, each hardness scale is automatically corrected in three sections: high, medium and low.
6. The test force can be automatically corrected by the standard dynamometer.
7. The set coordinate points can be saved for automatic end quenching test and batch detection, which greatly improves the efficiency.
8. Various fixtures can be customized and different samples can be tested in batches.
9. Powerful data processing functions, including: HR, Hb, HV and other hardness system conversion, setting the qualified range, automatic alarm for exceeding the limit, and inputting the tester, sample name and other information.
For more sample and test information, the measurement data USB flash disk is saved in Excel format, which is convenient for editing and processing.
Product Parameters
Technology parameter:
Model |
HLRS-150DX-ZXY |
Rockwell initial test force |
10kgf(98.07N) |
Rockwell total test force |
60kgf(588N) 100kgf(980N) 150kgf(1471N) |
hardness scales |
HRA,HRB,HRC,HRD,HRE,HRF,HRG,HRH,HRK, HRL,HRM,HRR,HRP,HRS,HRV |
Rockwell test range |
HRA:20-88,HRB:20-100 ,HRC:20-70 ,HRD:40-77 ,HRE:70-100 ,HRF:60-100 ,HRG:30-94,HRH:80-100,HRK:40-100,HRL:100-120 HRM:85-115, HRR:114-125 |
standard |
BSEN 6508, ISO 6508, ASTM E18, GB/T230 |
Duration Time |
0-99s |
Hardness value resolution |
0.1HR |
Test force error |
<0.5% |
data output |
LCD display |
data storage |
The measured value is saved in the USB flash disk in Excel format |
Exchange Scales |
Rockwell, Brinell, Vickers |
Maximum allowable specimen height |
The maximum height of X mobile station is 200mm, and the maximum height of X / y mobile station is 100mm |
Distance from indenter to machine wall |
200mm |
size |
560×280×850mm |
weight |
80kg |
Power Supply |
AC220+5%,50~60Hz |
Company Profile
Certifications
Packaging & Shipping