HLY-1000E computer controlled dual oil cylinder electro-hydraulic servo universal testing machine is suitable for tensile test and constant load stretching under rated test force. It can also be used for safety connection of bolts, connecting chains, high-strength links and bolts. Extension, compression and bending strength tests.
Meet the "GB/T 228.1-2010 tensile test of metal materials Part 1: room temperature test method", the electricalsystem has three control modes: force control, deformation control and displacement control. In the test process, three control modes can be set according to the setting. The program smoothly switches.
The software can automatically obtain ReH (upper yield strength), ReL (lower yield strength), Rp0.2 (specified non-proportional extension strength), Rt0.5 (specified total extension strength), Rm (tensile strength), E(elasticity) Modulus) and other parameters.
Model and specification | HLY-300E | HLY-600E | HLY-1000E | HLY-1600E | HLY-2000E |
Capacity (kN) | 300 | 600 | 1000 | 1600 | 2000 |
The host structure | single space four column, dual cylinder,frame structure | ||||
Accuracy class | 1 class (0.5class optional) | ||||
Test force range(kN) | 1%~100%F.S | ||||
Test force resolution | Capacity/500, 000 (fully auto scaling of single measurement range) | ||||
Test force accuracy | ±0.5% (±1% optional) | ||||
Deformation resolution | 500,000 | ||||
Deformation accuracy | ±0.5% | ||||
Displacement resolution(mm) | 0.001 | ||||
Displacement accuracy | ±0.5% | ||||
Adjusting range of stress-controlled velocity | 1MPa/s-100MPa/s | ||||
Relative error of stress-controlled velocity | ±1% (±2%) | ||||
Adjusting range of strain-controlled velocity | 0.00025/s-0.0025/s | ||||
Relative error of strain-controlled velocity | ±1% (±2%) | ||||
Range of force/ extension/ displacement- control | 0.3%~100%F.S | ||||
Accuracy of force/ extension/ displacement- control | Set value <10% F.S, ±1%, set value ≥10%F.S,±0.5% | ||||
Speed setting accuracy | ±0.5% (±1% optional) | ||||
Speed setting range (mm/min) | 0-250 | 0-200 | 0-150 | ||
Tensile space(mm) | 950 | 1100 | 1100 | ||
Space between columns(mm) | 650 | 850 | 1100 | ||
Piston stroke(mm) | 950 | 1100 | 1100 | ||
Diameter of round specimen(mm) | ∮6-∮50 | ∮8- ∮80 | |||
Thickness of flat specimen (mm) | 0-60 | 0-80 | |||
Dimension of load frame (mm) | 1100*740*2650 | 1370*800*3000 | 1740*960*3610 | ||
Dimension of control console(mm) | 1260*760*1150 | 1260*760*1400 | |||
Weight of load frame (kg) | 5000 | 9000 | 15000 | ||
Weight of control console | 800 | 1000 | |||
Power (kW) | 9, AC 380V ±10% | 18, AC 380V±10% |